BPZWQ - GRAM IODINE SOLUTION (STABILIZED)

Product Identification

Product ID:GRAM IODINE SOLUTION (STABILIZED)
MSDS Date:03/05/1990
FSC:6550
NIIN:01-315-5295
MSDS Number: BPZWQ

Responsible Party
BECTON-DICKINSON MICROBIOLOGY SYSTEMS INC
250 SCHILLING CIR
COCKEYSVILLE, MD 21030
US

Emergency Phone: 301-584-7169

Info Phone: 301-584-7169

Cage: 05545

Contractor
CURTIN MATHESON SCIENTIFIC INC
KENNESAW, GA 30144 US

Telephone: 404-590-9016

Cage: 8C742

Ingredients

IODINE (PART OF POVIDINE-IODINE COMPLEX-12.5%).

CAS: 7553-56-2

RTECS: NN1575000

OSHA PEL C 0.1 PPM

ACGIH TLV: C 0.1 PPM; 9293


2-POLYVINYL-PYRROLIDONE (POVIDONE-PVP) -AS PART OF THE

CAS: 9003-39-8

RTECS: TR8370000

Hazards

LD50 LC50 Mixture:LDLO(DOG)=800MG/K
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:CAN CAUSE IRRITATION.SKIN:MAY
CAUSE STAIN AND/OR IRRITATION.INGEST:MAY CAUSE BURNING SENSATION.
Explanation of Carcinogenicity:NOT APPLICABLE.
Effects of Overexposure:SKIN:STAINING.INGEST:BURNING SENSATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH WITH WATER FOR 15 MINUTES.SKIN:WASH AFFECTED AREA
WITH SOAP AND WATER.INGEST:GIVE 3 GLASSES OF WATER(ONLY IF
CONSCIOUS).CALL A PHYSICIAN IMMEDIATELY!

Fire Fighting

Extinguishing Media:MANUFACTURER SUGGESTS WATERSPRAY.
Fire Fighting Procedures:PRODUCT WILL NOT BURN.USE APPROPRIATE MEDIA TO
EXTINGUISH SURROUNDING FIRE.WEAR SELF-CONTAINED BREATHING
APPARATUS;TOXIC IODINE FUMES ARE EMITTED.
Unusual Fire/Explosion Hazard:TOXIC IODINE FUMES ARE EMITTED FROM HEAT.

Accidental Release

Spill Release Procedures:ADSORB LIQUID ONTO A PAPER TOWEL;DISPOSE OF IN
LAB TRASH.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:OTHER COMPONENTS OF THIS KIT ARE
FLAMMABLE;STORE AS FLAMMABLE.
Other Precautions:NONE

Exposure Controls

Respiratory Protection:NOT REQUIRED UNDER NORMAL USAGE.
Ventilation:GENERAL AND/OR LOCAL TO MEET TLV REQUIREMENTS.
Protective Gloves:NOT NNEDED UNDER NORMAL USE.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:EYEWASH STATION SHOULD BE AVAILABLE.
Work Hygienic Practices:WASH HANDS.USE APPROPRIATE HYGENIC AND SANITARY
PRACTICES.
Supplemental Safety and Health
CONTAINS 9-12% AVAILABLE IODINE.

Chemical Properties

HCC:T6
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:.3MM (I)
Vapor Density:9
Spec Gravity:4.98(IODINE)
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID;DARK BROWN;CHARACTERISTIC IODINE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
AMMONIUM HYDROXIDE.
Stability Condition to Avoid:HIGH HEAT,FLAMES.
Hazardous Decomposition Products:AMMONIUM HYDROXIDE REACTS(FORMS SHOCK
SENSITIVE IODIDES),AMMONIA,POWDERED METALS,ALKALI METALS.

Disposal

Waste Disposal Methods:MANUFACTURER STATES THAT MATERIEL CAN BE
DISPOSED OF WITH NORMAL LAB TRASH.FOLLOW FEDERAL,STATE AMD LOCAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.